V-STOP
DESCRIPTION: V-STOP WB is a hi-performance water based,
siloxane/silane water repellent. V-STOP WB-HD is formulated for use
on dense surfaces, such as brick, pre-cast, concrete block, or poured-in-place
concrete. V-STOP WB Heavy Duty is very suitable for porous surfaces
such as limestone, lightweight concrete, concrete block and mortar
joints.
FEATURES AND BENEFITS
o Waterproofs concrete and masonry
o Water-based, VOC Compliant
o Colorless
o Odorless
o Non-staining, Non-yellowing
o Reduce efflorescence and spalling
o Breathable
o Complies with SS W110C and ASTM E514
Will not alter texture or appearance of treated surface
WB Regular and Heavy Duty are proprietary, aqueous emulsions of siloxane/silane
oligomers
APPLICATIONS
Horizontal and vertical surfaces such as
o Concrete
o Concrete block
o Lightweight concrete
o Brick & Mortar joints
APPLICATION TECHNIQUES:
Low-pressure airless spray equipment is the preferred method of application,
although for smaller areas, application with brush or rollers may
also be acceptable. Application should be from the bottom up to ensure
uniform product distribution. Apply a saturation coat with a 6-8"
controlled rundown. For dense surfaces, one saturation coat of V-STOP
WB-HD is normally required. For porous surfaces two or more saturation
coats of V-STOP WB Heavy Duty may be required, applied using a "wet
on wet" technique. Apply a test patch to evaluate surface appearance
and effectiveness of the coverage rate.
SURFACE PREPARATION:
Cure new concrete 28 days before application. Surface should be structurally
sound, clean, dry, free of dust, dirt, paint, efflorescence, laitance
and other contaminants that will prevent the proper penetration of
V-STOP WB-HD.
A dry substrate is required for proper penetration of the sealer.
Prior to application, joints or cracks must be properly sealed or
filled. If acid is used for cleaning, neutralize completely before
application of V-STOP WB-HD. A dry substrate allows better penetration
of the sealer.
Material Properties @ 75° F, 50% RH
Regular Heavy Duty
Weight/gallon, lbs. 8.35 8.40
Viscosity, cps 50 50
Depth of Penetration
(sub. dependent) 3/8" 3/8"
Reduction in water leakage (ASTM E514-90)
Brick ----- 100%
Mortar Block ----- >91%
Reduction in water
absorption, SSW110 90.5% 92.3%
Flash point (°F) >200 >200
Accelerated weathering
1500 hours No Change No Change
Abrasion Resistance Excellent Excellent
Dirt Pick-up None None
VOC 25 gms/liter 50 gms/liter
COVERAGE RATES
The following coverage rates are approximate and for estimating purposes
only: Make test applications on actual surfaces to determine more
accurately the coverage rates and effectiveness of water repellent.
When two coats are required, apply the second coat on the still wet
V-STOP WB-HD by following the "wet on wet" technique. V-STOP
WB-HD will yield appx. 40-60 sqft. 1st coat and 60-100 sqft. 2nd Coat.
Values presented are typical and are not necessarily referenced to
create specifications.
Clean-Up
Clean drips, runs, and overspray residue while still wet, using
detergent and water. V-STOP WB-HD will not etch common glass; spills
and overspray onto glass can be easily removed with a damp cloth.
Dried material may require mechanical abrasion for removal. Clean
application and spray equipment with detergent and water immediately
following use.
Environmental & Safety
ENVIRONMENTAL AND SAFETY PRECAUTIONS: Industrial Use Only.
V-STOP WB-HD products are non-flammable and non hazardous. Avoid splashing
into eyes or contact with skin. In case of eye contact, flood eyes
repeatedly with water and call a physician as needed.
DO NOT RUB EYES! Avoid breathing vapors or mist. Wash hands thoroughly
after handling, and before smoking or eating. Do not take internally.
Keep away from children and animals. Protect shrubbery, plants, grass,
glass, metal and asphalt surfaces during application. Consult Material
Safety Data Sheet for complete product information. EMERGENCY RESPONSE
PHONE NUMBER: (800) 8622667 OR (800) 424-9300 CHEMTREC.
Cautions
Do not dilute. Temperature of air and surface must be at least 45°F
and rising. Application at temperatures above 90°F is not recommended.
Do not apply if rain is expected within 12 hours of application. Water
repellency properties will develop 24 hours to 5 days after application.
V-STOP WB-HD is not intended to seal cracks or withstand hydrostatic
pressure. Uneven application may result in a blotchy appearance of the
surface. Do not apply a "fog" coat.